| Model | Logical processors |
HP® PA-RISC microprocessor speed |
Cache
per processor |
# slots
in main chassis |
| Continuum 1252-2 | 2 | 480 MHz | 1.5 MB | 12 |
| Continuum 1252-1 | 1 | 480 MHz | 1.5 MB | 12 |
| Continuum 652-2 | 2 | 480 MHz | 1.5 MB | 6 |
| Continuum 651-2 | 1 | 480 MHz | 1.5 MB | 6 |
| Continuum 1229 | 2 | 380 MHz | 1.5 MB | 12 |
| Continuum 1219 | 1 | 380 MHz | 1.5 MB | 12 |
| Continuum 629 | 2 | 380 MHz | 1.5 MB | 6 |
| Continuum 619 | 1 | 380 MHz | 1.5 MB | 6 |
| Continuum 616 | 1 | 360 MHz | 1.5 MB | 6 |
| Continuum 616S | 1 | 360 MHz | 1.5 MB | 6 |
| Continuum 1228* | 2 | 180 MHz | 2 MB | 12 |
| Continuum 1218* | 1 | 180 MHz | 2 MB | 12 |
| Continuum 628* | 2 | 180 MHz | 2 MB | 6 |
| Continuum 618* | 1 | 180 MHz | 2 MB | 6 |
| Continuum 1225* | 2 | 96 MHz | 2 MB | 12 |
| Continuum 1220* | 2 | 96 MHz | 2 MB | 12 |
| Continuum 625* | 2 | 96 MHz | 2 MB | 6 |
| Continuum 620* | 2 | 72 MHz | 512 KB | 6 |
| Continuum 610* | 1 | 72 MHz | 512 KB | 6 |
* Discontinued models are subject to availability.
| Physical and Operating Specifications for all Continuum 600, 1200 Models | |
| Cabinet Dimensions | |
| Height: | 180.3 cm (71 inches) |
| Width: | 76.2 cm (30 inches) |
| Depth: | 102 cm (40 inches) |
| Weight: | 545.5 kg (1,200 lbs) maximum |
| Environment | |
| Operating Temperature | |
| Installed at: | |
| -200 to 6,000 ft | 4.5 deg. to 40 deg. C (40 to 104 F) |
| 6,000 to 8,000 ft | 4.5 deg. to 35 deg. C (40 to 95 F) |
| 8,000 to 10,000 ft | 4.5 deg. to 30 deg. C (40 to 86 F) |
| Short-Term (< 72 hours) Operating
Temperature (DC systems only) |
|
| Installed at: | |
| -200 to 6,000 ft | 1.7 deg. to 49 deg. C (35 to 120 F) |
| 6,000 to 8,000 ft | 1.7 deg. to 45 deg. C (35 to 113 F) |
| 8,000 to 10,000 ft | 1.7 deg. to 35 deg. C (35 to 95 F) |
| Maximum Rate of Temperature Change: 12 deg./hr C (21.6 deg./hr F) |
|
| Relative Humidity: | 10% to 80% non-condensing |
| Acoustical Noise: | 68 dba maximum (per cabinet) |
| Maximum Heat Dissipation (per cabinet) |
|
| AC operation: | 15,131 Btu/hr |
| DC operation: | 12,283 Btu/hr |
| Electrical | |
| AC Input Voltage Range | |
| Nominal: | 200 to 240V AC |
| Absolute: | 180 to 264V AC |
| AC Input Frequency: | 47 to 63 Hz |
| AC Input Power (total): | 4.44 KVA |
| AC Input Current (nominal): | 22.2 amp @ 200V AC |
| DC Output Voltage Range | |
| Range: | -40 to -59.9V DC |
| Nominal: | -54.5V DC |
| Maximum DC Load Power: |
3,600 W |
| AC Line Cord (dual) | |
| Length: | 4 m (15 ft) |
| Termination | |
| Domestic: | NEMA 30 amp, 250 V twist-lock connector |
| International: | IEC 309, 32 amp, 250 V pin-and-sleeve connector |
| DC Input Voltage (CO system) | |
| -42.0 to 59.9V DC | |
| DC Line Cord (dual) | |
| Length: | 7.6 m (25 ft) |
| Termination: | Double-holed ring lug connector |
| Specifications subject to change. | |